• Contact factory : +233593223368 / 0544003425

Dental Chair

Handpieces, Curing Light , Memory , Whitening device , Woodpecker Led Scaler , air compressor,Oral camera system, Position Selection Valve, Monitor arm , Cup holder and shelf .

Product Detail

Standard Configuration: (2/4-hole) high-speed air turbine handpiece’s connector 2 sets (2/4-hole) low-speed air turbine handpiece’s connector 1 sets Three-way syringe(cold and hot) 1 Set each Down-mounted tool tray 1 Set All directional headrest 1 Set Rotary assistant tray 1 Set 24V X-film viewer 1 Set Operation lamp 1 set (Halogen or Led) Strong and weak suction 1 Set each Water heating system 1 Set Outlay pure water bottle 1 Set Rotatable ceramic spittoon 1 Set. (Can change to Glass spittoon ) Without Memory PU Leather Cushion 1 set (Colors in below photo) Dentist stool VIC-009 1 piece Size :130cm*100cm*76cm (container packing size) LCL Package size: 142cm*100cm*120cm Warranty: 2 Years Square foot pedal VIC-106 1 piece( Can change to Mutil-fuction Foot Pedal) Floor box type: outlaid floor box (Also can unit-box built-in) Power:220V,Plug type :England style

( The plug can change as your requirement ) MOQ: 5 Units (can mix with other models or other equipment ) Optional Configuration: Handpieces, Curing Light , Memory , Whitening device , Woodpecker Led Scaler , air compressor,Oral camera system, Position Selection Valve, Monitor arm , Cup holder and shelf ..

Installation Preparation: Decide where to install the machine according to the overall arrangement,lighting and avaiability of the clinlc.Put the machine in a clean,dry,draughty and cool place as good working conditions.Make sure that the dental chair chassis contacts the even and solid floor.Under the floor box,there must be inlets/outlets for water,gas and electricity for the machine within the range of l40X120mm.The water inlet pipe and air intake pipe should be the 8X5 pipes.The drainpipe should be the hosepipe at中Φ40mm(3/2”).The port of each pipe is about 40mm away from the the floor.The input wire should be the 3—core 1mm Jacketed cord.about 40mm away from the floor.And connect the protective ground wire well.For the detailed dimensions,please see Fig.2. Unpacking inspection: Unpack the W/CASE to verify that the whole machine is intact. And check whether the accessories and spare parts are complete and intact according to the packing list.For any questions,please inquire the dealer or our company at once. Installing the main unit Firstly,put the dental chair in the right place.The design of this machine considers the stability of the whole machine,so the foot-fixing screws are unnecessary.But the dental chair chassis must contact the even and solid floorfor fear of accidents In case of rotation or declining of the whole machine due to the uneven floor,one can fasten the six M12 inner hexad flat end fixing screws into the six M10 screwed boles on the dental chair chassis,and make it fully contact the floor.During the adjustment,Please keep the whole machine even and guarantee as many contact points as possible,so as to ensure the stability of the whole machine. 4. Installing the mouth lamp Put the wire from the light arm through the lampstand,and then connect the two well.After that.connect the wire connector on the lamp arm to that in the dental cabinet,and put them into the column.Then put the lampstand onto the column,and put the lamp arm in the right place(Note:don’t damage the wire.) Connect the lamp base wire inserter through the decorative jacket to the lamp arm wire inserter,insert the lamp base handle into the lamp arm hole,and fasten with screws(see Fig.3),and then cover the screw and seam with the decorative jacket. Installing the base Pipeline connection Power connection Installing the hand-piece

Testing and adjustment Turbine hand-piece(optional) Connect water and air pipeline and power supply. The water pressure should be maintained between 0.2~0.4MPa, and an excessively low pressure will not be able to ensure supplying the water required for normal operation, while an excessively high pressure will affect the water-tightness of unit. The regulating range of filter-regulator should be 0.55~0.6Mpa, and if this is not the case, the filter-regulator should be adjusted accordingly to ensure that air pressure is within the correct range. To do so, open the base cover, pull up the rotating handle on the top of filter-regulator for about 10mm(as shown in figure 4), then rotate the handle clockwise for greater pressure and anticlockwise for smaller pressure. The turbine hand-piece is a precision part. Please read product manual before using the turbine hand-piece The water used by the hand piece directly comes from the water tank whose output pressure is determined by the pressure of air entering the water tank, while the air pressure is controlled by a dedicated reducing valve provided inside the base of dental unit. To check the pressure, open the base cover and check the pressure meter on the reducing valve, whose value should be 0.2MPa, and if this is not the case, the reducing valve should be adjusted accordingly to achieve this value. The method is same as that for adjusting the filter-regulator. Pick up the turbine hand-piece from the hanger and step on the pneumatic-control switch(large switch), the hand piece will rotate and cooling water will be ejected, and the hand piece is ready for operation. Attention: at this time, the pressure indicated by the pressure meter on the instrument tray is the working pressure of hand piece (*1), which must not exceed the rated maximum pressure to prevent damage. If the working pressure needs to be adjusted, please use the main control valve provided on the back of instrument tray for the purpose(as shown in figure 5). Turn it clockwise for smaller pressure and anticlockwise for greater pressure, and please adjust carefully by degrees. When the small switch is pressed, the hand piece will not rotate, but only send out air for blowing off chips. Attention: Please remove the dental bur only after the high-speed or low-speed hand-piece is fully stopped or it may cause damage to the bur holder, the bur may fall off and cause injury to human. Only high quality dental bur and bolts with suitable size should be used. Before starting every day’s work, please check the condition of bur holder to make sure that the bur is securely fastened into the hand piece. After replacing the bur in high-speed hand piece, try pulling it outwards to make sure that it is properly installed. The bur diameter should be between 1.59 -1.60mm(ISO1797 Category III) and the maximum length should be 25mm(ISO6360-1). The high-speed hand piece may only be used when a bur or repair tool is installed. When the unit is in use, please do not press the bur release button because the friction between the button and the impeller of pneumatic motor will cause overheating in the head and may result in damage. 2. Saliva aspirator The unit is equipped with a saliva aspirator which will be ready for working when it is picked up from the hanger. As water is needed for weak suction, water supply must be connected and the minimum working pressure must be ensured. Suction (low) is water suction. Connection through water source is required, and minimum water level is required to be ensured; suction (strong) is air suction. Connection through air source is required, and minimum air level is required to be kept 3. Water storage bottle The water used by the hand piece directly comes from the water storage bottle, and it is necessary to fill medical distilled water into the bottle in a timely manner. The way of filling water: turn off the air lock on the chassis and wait until the compressed air inside the bottle is discharged, hold the bottle with both hands and rotate it clockwise to remove it, fill water in it and rotate anticlockwise to press it tight against the bottle cap (paying attention to water-tightness), reinstall the bottle, turn on the air lock and the filling process is completed. 4. Headrest The unit’s headrest can be adjusted between two positions including the adult position and children position, and the rotating angle and height of headrest are adjustable for these two positions(as shown in figure 6). To adjust the rotation angle, just hold the headrest, turn handle 1# to the required position and then tighten the handle. To adjust the height, simply pull up or push down the headrest to the required height, and the optimal position can be achieved by combining angle and height adjustment. Attention: it is important to ensure that the headrest is used only after it is securely locked into place after adjustment to prevent accident during use. Attention: because the backrest of dental chair has a large range of motion, it is necessary to ensure that no object which may come into contact with the backrest exists within the range during operation in order to prevent accident. Remark: *1. Technically, between the pressure indicated by the pressure meter on instrument tray and the actual working pressure of hand piece, there is a certain difference, which is exactly the pressure loss at the pipeline of hand piece. However, from the user’s perspective, it is important to regard the pressure indicated on the instrument tray as the working pressure of hand piece in order to prolong its service life..

Related Products

Dental Chair

Handy Sensor

Light Cure Composite
Unit

Micro Motor

Multisystem Dental Implant Screw

Dental Examination Set

Dental Examination dental-extraction-forceps-kit-

Ortho Plier

About US

Adam And Medical World Ltd. is an Importing and Manufacturing company in West Africa- Ghana since 2005. Our company is registered in Public Procurement Authority (PPA), supplier # 944984. Adam Dental And Medical World Ltd. main range of items includes dental materials, instruments and equipment. We are the only agent for different Dental factories and companies in Ghana and West Africa:Major/Italy, Pyrax/India, TG/UK, Lingan/India, Haiju/ China, VVDental/China, Janbro/Pakistan , MultySystem Dental Implant /Italy, Modern Orthodontics /India ,Handy /China ,Smile Strong/Italy etc…

  • 23 Rose Stren Melbourn
  • adam_meddentworld@yahoo.com
  • +233244041111 / +23320920073

Latest Posts

Get your smile shining! Discover our latest dental products for a healthy and confident grin

Stay ahead of your dental game! Check out our newest arrivals

Revolutionize your dental care! Explore our latest offerings and achieve a brighter

News Letter

"Stay in the know with our dental newsletter! Get exclusive updates on the latest dental products, oral care tips, and special promotions. Don't miss out on the opportunity to achieve a healthier smile. Subscribe to our newsletter today and join our dental community!".